Panel 3210 - Security/Fire Alarm Control Panel (S/FACP)
The 3210 S/FACP provides real-time detection and notification of alarm conditions
to all registered workstations.
3210 Features
User-friendly touchscreen graphic display provides intuitive easy-to-use interface for both the skilled and novice users. Intergral key-activated login for first responders.
Redundant monitoring architecture allows multiple monitoring stations to monitor a single alarm panel while each monitoring station can also monitor multiple alarm panels.
Up to 30 addressable 3220 DIUs may be connected to any single 3210 S/FACP alarm panel (up to 1920 points).
Rugged enclosures are fabricated from heavy-duty steel. Durable powder cost finish. Convenient lift-off hinges make installations quick and easy.
Rapid alarm notification. A 3220 DIU is polled every 1/30th of a second by the S/FACP.
Tamper switch detects when cover is open, alerting 3210 S/FACP.
Communication integrity continuously checked between 3220 DIU and 3210 S/FACP. Failure produces trouble notification at each device. Redundant communications loop provides backup path. Failed network communication generates alarms at both S/FACP and at monitoring stations.
Internal backup power supply insures 24 hours of uninterrupted operations without primary power.
Panel 3220 - Device Interface Unit (DIU)
The 3220 Device Interface Unit interfaces the System 3000 with the sensors and control units.
3220 Features
Modular design allows for more flexible configuration of point types. Supports four Application Specific Module (ASM) board slots.
Up to 64 points/DIU, when populated with four (4) 16 channel supervised input boards (Model 3220-01, ASM-SI16).
Up to 30 addressable 3220 DIUs may be connected to any single 3210 S/FACP alarm panel (up to 1920 points).
Rugged enclosures are fabricated from heavy-duty steel. Durable powder cost finish. Convenient lift-off hinges make installations quick and easy.
Rapid alarm notification. A 3220 DIU is polled every 1/30th of a second by the S/FACP.
Tamper switch detects when cover is open, alerting 3210 S/FACP.
Communication integrity continuously checked between 3220 DIU and 3210 S/FACP. Failure produces trouble notification at each device. Redundant communications loop provides backup path. Failed network communication generates alarms at both S/FACP and at monitoring stations.
Internal backup power supply insures 24 hours of uninterrupted operations without primary power.
Interconnecting the 3210 & 3220 Panels
The 3210 S/FACP connects to the 3220 DIU over a redundant pair of 4-wire RS485 ports.
ASMs - Application Specific Modules
3220-01 - ASM-SI16
The 3220-01 supervised 16-channel input board is an application specific module designed
exclusively for the System 3000 3220 DIU. The ASM-SI16 provides sixteen (16) input channels
that may be used to receive reported changes in standard four-wire detection and two-wire
contacts like a pull station.
3220-03 - ASM-ST16
The 3220-03 supervised 16-channel digital temperature sensor board is an application specific module
designed exclusively for the System 3000 3220 DIU. The ASM-ST16 supports communication with up to 16 Model 3310-01 Digital Temperature Sensors (DTS).
3220-04 - ASM-SO08
The 3220-04 supervised 8-channel output board is an application specific module
designed exclusively for the System 3000 3220 DIU. The ASM-SO08 provides (8) eight output control channels that may be used
to activate horns/strobes through a power booster extender or may simply actuate a relay (i.e. light control).
3230-01 - Security Keypad (Under Development - Available 2010)
The Security Keypad will allow access to security zone arming and disarming. In addition the keypad
will display the state of a security zone, display a list of points blocking an Arm command and allow
users to bypass the blocking point. The 3230-01 Security Keypad will communicate directly to the
3210 S/FACP via an RS-485 multidrop link.